Helped customer solved leaking of FUJI NXT H12 head filter element AA0AL00

Vous êtes ici: Domicile » Nouvelles & Épreuves » Helped customer solved leaking of FUJI NXT H12 head filter element AA0AL00

NXT H12 head filter element AA0AL0 original new

Copy new ELEMENT H12 head NXT FILTER AA0AL00:

Different size of o-ring
baseplate deformities
Head washer vacuum leak

Head H12
under sealed by
syringes
Value from 26 À -31 PSI

Brand new filter AA0AL00 testing feedback:

Symmetrical and wider O-ring
No deformity in base nozzle
Better sealing in FUJI NXT head

Head H12
best sealed by
syringes
Value from 29 À -33 PSI